2021
Sex Differences in Intracoronary Imaging and Functional Evaluation of Coronary Arteries
Velagapudi P, Altin S, Schneider M, Alasnag M. Sex Differences in Intracoronary Imaging and Functional Evaluation of Coronary Arteries. Current Cardiovascular Imaging Reports 2021, 14: 7. DOI: 10.1007/s12410-021-09557-3.Peer-Reviewed Original ResearchIntracoronary imagingArtery diseaseCoronary arteryNon-obstructive coronary artery diseaseSpontaneous coronary artery dissectionFunctional evaluationChronic coronary syndromeCoronary artery dissectionCoronary artery diseaseConventional coronary angiographyRecent FindingsThe diagnosisTreatment of womenOptical coherence tomographySex differencesSex-based differencesArtery dissectionCoronary syndromeMicrovascular dysfunctionCoronary angiographyMicrovascular functionClinical outcomesHyperemic responsePlaque characteristicsMyocardial infarctionBroad pathology
2020
Long‐term serial functional evaluation after implantation of the Fantom sirolimus‐eluting bioresorbable coronary scaffold
Saito Y, Cristea E, Bouras G, Abizaid A, Lutz M, Carrié D, Weber‐Albers J, Dudek D, Anderson J, Lansky A, Investigators T. Long‐term serial functional evaluation after implantation of the Fantom sirolimus‐eluting bioresorbable coronary scaffold. Catheterization And Cardiovascular Interventions 2020, 97: 431-436. PMID: 32077590, DOI: 10.1002/ccd.28804.Peer-Reviewed Original ResearchConceptsPost-percutaneous coronary interventionQuantitative flow ratioBioresorbable coronary scaffoldTarget vessel revascularizationVessel revascularizationFunctional ischemiaStable coronary artery diseaseTime of revascularizationCoronary artery diseaseFractional flow reserveQFR assessmentII trialAngiographic outcomesCoronary interventionUnstable anginaArtery diseaseQFR valueWire-based fractional flow reserveSignificant lesionsFlow reservePatientsTarget vesselRevascularizationQFR analysisFunctional evaluation
2019
TCT-177 Long-Term Serial Functional Evaluation After Implantation of the Fantom Sirolimus-Eluting Bioresorbable Coronary Scaffold: The FANTOM II study
Saito Y, Bouras G, Abizaid A, Lutz M, Carrié D, Weber-Albers J, Anderson J, Lansky A. TCT-177 Long-Term Serial Functional Evaluation After Implantation of the Fantom Sirolimus-Eluting Bioresorbable Coronary Scaffold: The FANTOM II study. Journal Of The American College Of Cardiology 2019, 74: b176. DOI: 10.1016/j.jacc.2019.08.234.Peer-Reviewed Original Research
2013
Blood pressure hyperreactivity
Kunrath J, Gurzau E, Gurzau A, Goessler W, Gelmann ER, Thach TT, McCarty KM, Yeckel CW. Blood pressure hyperreactivity. Journal Of Hypertension 2013, 31: 361-369. PMID: 23203141, PMCID: PMC3542419, DOI: 10.1097/hjh.0b013e32835c175f.Peer-Reviewed Original ResearchConceptsBlood pressure hyperreactivityBlood pressure recoveryHypertensive responseUnexposed groupMiddle-aged menCold pressor testInorganic arsenic exposureInorganic arsenicCardiovascular stress reactivityNormotensive menBlood pressureEssential hypertensionHypertension riskPressor testHyperreactivityChronic exposureArsenic exposureArsenic-endemic regionEarly signsStress-induced changesFunctional evaluationUrine samplesDrinking waterStress reactivityGreater probability
This site is protected by hCaptcha and its Privacy Policy and Terms of Service apply